| Performance Data |
| Frequency |
50.0 - 100.0 MHz |
| P1dB Compression Point |
12 dBm Typical 10 dBm Min |
| Harmonics |
-15 dBc Typical -10 dBc Max |
| Phase Noise |
-130 dBc/Hz Typical @ 100 kHz |
| Power Supply |
15 Volts 14 mA |
| Tuning Voltage |
0 to 20 V |
|
|
| Package Drawing |
 |
Note: Care should always be taken to effectively ground the case of each unit. |
|